It also controls the timing, synchronization, and data transfer between C Series I/O modules and an external host. The "Data Rates" section of the NI-9234 Datasheet explains how the minimum sampling rate is determined for any given timebase. Watch this video or follow the instructions provided. Find many great new & used options and get the best deals for National Instruments NI cDAQ-9178 USB CompactDAQ Chassis, 8-Slot 781156-01 at the best online prices at eBay! Free shipping for many products!8‑Slot, USB CompactDAQ Chassis —The cDAQ‑9172 provides USB connectivity for small, portable sensor measurement systems. 8‑Slot, USB CompactDAQ Chassis. com de dos maneras: Correo electrónico de reclamación de software: Después de comprar LabVIEW u otros módulos. cDAQ-9184 Firmware and Additional Driversをダウンロードして、サポート情報をご確認ください。. The cDAQ‑9179 is a CompactDAQ USB chassis designed for small, portable sensor measurement systems. Connect the NI cDAQ-9178 chassis to the system safety ground. The chassis provides the plug‑and‑play simplicity of USB to sensor and electrical measurements. com. The Device class of the NI-DAQmx C# API has a Reset method included as part of the class. Find the heading titled Universal Serial Bus controllers and expand it. The chassis provides the plug‑and‑play simplicity of USB to sensor and electrical measurements. This file contains installation instructions and compatibility information for NI-DAQmx. Controlador NI-DAQmx. 3. A newly installed device typically has a name like "cDAQ1": Open LabVIEW. NI cDAQ-9178 Chassis and NI 9401 Digital I/O Module. Launch NI MAX. Connect the NI cDAQ-9178 chassis to your host computer. NI-DAQmx provides multiple functions for reading and writing data. 02-17-2017 09:58 AM - edited 02-17-2017 10:02 AM. Modules that accept an external master time bases are. Connect the NI cDAQ-9178 to the system safety ground. When PC restarts, reconnect and check the device. National Instruments cDAQ 9178: DAQ software: LabView Express: Blower: Dayton Electric Mfg. Sie haben nun die LabVIEW-Software installiert, die Sie für Ihr CompactDAQ-System benötigen. 0 scans/sec 32 channels ('ai0' - 'ai31. The cDAQ-9178 is a CompactDAQ USB chassis designed for small, portable sensor measurement systems. 3. Other customers have asked for supporting the built-in PFI lines as well, and we. You can use this chassis with a combination of C Series I/O modules to create. cDAQ-9178 USB-6212 Driver. NI cDAQ-9178 Dimensions 1 2 3 4 5 6 7 8 19. 01-21-2021 08:38 AM. It includes a high-resolution mode with 50/60 Hz rejection to remove low frequency noise. Each chassis must have one NI-9469 to be installed, so two NI-9469 are required in this case. 1. Kevin_Price. (b) Heating test equipment, on the front the heater, on the back from left to right, DC power supply, data logger,. I am trying to trigger my cDAQ-9178 on the chassis PFI0 line. NI-DAQmx Readme Updates. Learn how to install, configure, and acquire data from your NI CompactDAQ USB. You can use the Industrial Rack Mount. This page provides documents in a variety of file formats that are compatible with most commercial third-party CAD software. NI cDAQTM-9171/9174/9178 User Manual NI CompactDAQ USB 2. With NI MAX open, start by refreshing the list of connected devices by clicking View»Refresh. 价格不含税。. Our free 2-year warranty makes every Radwell purchase a dependable, reliable investment in your company's future. In MATLAB, the following features of NI. The cDAQ-9178 chassis is shipped with the following: - AC/DC converter that plugs directly into the chassis - USB cable with a thumbscrew lock for strain relief Power cord sold separately. Manufacturer Product Number. Connect the ring lug to the ground terminal on the side of the NI cDAQ-9178 using the ground screw. 2 represents multiple data acquisition signals from the manometers [(i)–(k) in Fig. 01-30-2023 09:01 PM. 8 When operating the NI cDAQ-9178 in temperatures below 0 °C, you must use the PS-15 power supply or another power supply rated for below 0 °C. 0 kHz signal, they can select the 100 kHz base clock and a divisor of 2, the following table shows a truncated version of possible frequencies. The NI cDAQ-9178/9174 chassis is capable of measuring a broad range of analog and digital I/O signals and sensors using a. This example shows how easy it is to write a program in LabVIEW to accomplish concurrently reading 3 different rates with 3 different devices in the 9178 chasis. See all Driver Software Downloads. 4. b. It also controls the timing, synchronization, and data transfer between C Series I/O modules and an external. 如果上一部分出现“检测到的设备” (Device Detected)窗口,则通过该窗口启动。. The accel-Le cDAQ‑9178 est un châssis CompactDAQ USB, conçu pour des systèmes compacts portables de mesure par capteur. This page documents all the applicable standards and certifications for the cDAQ-9178 and provides downloadable certifications. I have a cDAQ-9178 with NI 9221 connected taking 3 pressure readings. Re: CDAQ9178 & NI9775. You can use this chassis with a combination of C Series I/O modules to create a mix of. JensG69. Scenario 2 - I have recently procured new cDAQ - 9178 for new ATE but it is not detecting PXIe but the same works in Host System. Proven Zealot. You can use this chassis with. All singles are processed by the LabVIEW data acquisition system, which consists of an industrial computer, a NI cDAQ-9178 data acquisition board, two NI 9213 modules to obtain temperature and four NI 9203 modules to obtain current signals of pressure transducers. 2 mm (0. All sensors were recorded at the same sample rate of 10 Hz. 1 GB (32-bit), 2 GB (64-bit) of RAM. Counter reads, for example, can return integers or floating-point formats. To do this hold down the Reset button for more than 5 seconds and then release it. 8‑Slot, USB CompactDAQ Chassis. コミュニティ. The NI cDAQ-9178 chassis served as the core control with an internal bus that sampled external analog input electrical signals at different sampling frequencies. First, ensure that you are using NI-DAQmx 8. Ultra-high purity grade oxygen, nitrogen, argon (>99. Plugged in the chassis (with 9411 in slot 1), and it detected as USB Firmware Loader in device loader, white icon with red x in MAX. 58 ISSN: 2355-7524 Modul chassis CDAQ 9178, modul termokopel NI 9213 dan modul arus 9203 dapat dilihat pada Gambar 3. 1 mm (0. b. I am using 2 of the counters to read frequency measurements. Order today, ships today. 1. The NI cDAQ-9178 (eight slots) and NI cDAQ-9174 (four slots) USB chassis are designed for use with C Series I/O modules. To discover a device that supports analog outputs, access the device in the table returned by the daqlist command. 0 mm (0. The instrument gives the straightforwardness of quick association (plug-and-play) of USB to its electrical and sensor estimations. 2. Microphones at additional polar angles were in the propeller’s wake which made the measurements inaccurate. 1TDP5: Before the charging cycle, the air-blower was connected to the top side of the packed-bed system. 0 communication. 8, was composed of National Instrument CompactDAQ (cDAQ-9178 with eight channels [21]) and a measurement card (NI 9234 [22]). 1 mm (3. The chassis provides the plug‑and‑play simplicity of USB to. The cDAQ‑9178 is a CompactDAQ USB chassis designed for small, portable sensor measurement systems. The cDAQ-9178 is a CompactDAQ USB chassis designed for small, portable sensor measurement systems. EDIT: for anyone interested, I now have this working in the following way, with a live visual feedback using matplotlib, and - not 100% percent sure yet - it seems there no buffer problems even if one aims at. The Gen II CompactDAQ chassis support a maximum of two synchronization pulse signals configured for your system. Open NI MAX and select your device from the Devices and Interfaces drop-down menu. 2. The program below was created for a cDAQ-9178 which does not support adjusting the frequency while the DAQmx task is running. The hermetic reciprocating compressor is thenThe surface of the workpiece is Z = 0 mm, when the position of the tool tip is Z = 1 mm, the command is given to start the simultaneous acquisition on the NI USB 6361 and NI cDAQ 9178 acquisition cards. 在本节中,以使用ni cdaq-9178机箱和ni 9401 c系列数字量i / o模块为例。使用其他测量仪器或设备时,此过程类似。 图8. Free shipping. Description. This type of ferrite is available from National Instruments (part number 781233-01). Scenario 1 - I have one cDAQ - 9178 and it works perfectly fine in one of our ATE (Automated Test Equipment). Finally, data acquisition was performed using a National Instruments Compact DAQ Chassis cDAQ-9178 housing an NI-9219 C Series Universal Analog Input Module. Amplitude information of the signals from the electronics attached to the scintillator-coupled multi-anode PMTs was collected using a data acquisition board (cDAQ-9178), and the timing information was sent to a FPGA (SPARTAN3E). NIの集録および信号調整デバイスをサポートします。. Figure3shows FIG. The DAQ is outputting a counter signal for controlling a motor (or a similar device). cDAQ comes in two main flavors: with a controller, and without a controller. Enter IP address obtained in Step 1 in the Add Device Manually as. Part Number: 196654C-01L, 781156-01. To verify the proposed design criteria, an open-circuit small-scale wind tunnel was built and tested. Buy 781156-01 - Ni - Chassis, cDAQ-9178, CompactDAQ Systems, 8 Slots, USB 2. The internal signals of the machine were acquired at the CNC itself. MXI-Express DAQ Chassis on a standard 19-inch rack. Download : Download high-res image (286KB) Download : Download full-size image; Fig. If you recently installed to a newer version of LabVIEW, try repairing the DAQmx driver. National Instrument NI cDAQ-9178 Manual Start DAQExpress: Step 1: Turn on the system by connecting to an outlet using output number 4 above. . data0 = sin (linspace (0, 2*pi, 1001))'; data1 = sin (linspace (0, 2*pi, 1001) + pi/4)'; data2 = sin (linspace (0. In many cases, you can use multiple options. Member. In principle this should thus go from 0 to 1 Volt in 1 second. Analog Input Analog Output Digital Waveform Characteristics The National Instruments cDAQ-9178 is a CompactDAQ Chassis (Part Number: 781156-01) intended for little, versatile sensor estimation frameworks. The minimum sample rate for the NI-9234 depends on the master timebase. The sinusoidal forcing and the additive Gaussian noise are both generated by LabVIEW and transmitted to the Brüel and Kjaer electro-dynamic shaker, via an NI cDAQ-9178 with an NI 9263 module. Order by Part Number or Request a Quote. . Dan_N. El chasis brinda la sencillez de conexión rápida (plug‑and‑play) del USB a sus medidas eléctricas y de sensores. Injection was controlled using an EFS xIpod piezoelec-tric injector driver. It also controls the timing, synchronization, and data transfer between C Series I/O modules and an external host. 3. 3. 6 mm) wire. También controla la temporización, la sincronización y la transferencia de datos entre los módulos de E/S de. It also controls the timing, synchronization, and data transfer between C Series I/O modules and an external host. 如果您的设备或模块确实出现在Windows设备管理器中,请检查其显示的类别。. cDAQ-9178 寸法図8-Slot, TSN-Enabled Ethernet CompactDAQ Chassis. Scenario 1 - I have one cDAQ - 9178 and it works perfectly fine in one of our ATE (Automated Test Equipment). Zanoofar. 8 | NI cDAQ-9178 Specifications | ni. 3. These specifications are typical at 25 °C unless. Thermocouple and pyranometer arrangement (unit: m). Warranty Terms and Conditions. 3. Select Find Network NI-DAQmx Devices. I connected the power cable to the NI 9178. NI-DAQmx 21. 1) using windows 10 operating system 64 bit. The USB-IF has defined a maximum cable length of 5m for USB 2. 例如,X系列板卡上的默认时钟源是板载时钟(100MHz)。. It also controls the timing, synchronization, and data transfer between C Series I/O modules and an external host. 50An impulse excitation was applied to the milling tool tip using an impact hammer (PCB 086D05) in directions collinear with the X, Y, and Z axes of the sensor. 2). Figure 12: NI cDAQ-9178 with two BNC ports can be used to import or export timing and trigger signals. 指定采样率的值取决于DAQmx定时函数的源输入端中指定的时基。. If you use the DAQmx Start Trigger VI it will be listed in the trigger source input pulldown. . The cDAQ‑9178 is a CompactDAQ USB chassis designed for small, portable sensor measurement systems. This guide is intended to cover power supply connectors for use with your CompactDAQ Controller and CompactDAQ Chassis. I tried it anyways and now. 4. Well it does not, and there is another problem (see below). From the NI 9411 pinout diagram (see pdf file attached to this post), these are the connections I made: CTR 0 SRC, pin 1 to COM/ground. It also helps you control the timing, synchronization, and data transfer between C Series I/O modules and an. Locate the cDAQ in NI MAX, and note its name. Step 2: Connect the USB cord. 2 are used to read data from ultrasonicsI am attempting to switch a system running on Windows XP to a Windows 64 bit computer. Descargue LabVIEW Los clientes pueden tener acceso a las descargas de software de ni. 196654-01L. c) Attach the other end of the wire to the system safety ground. The estimation particulars, including number of channels, channel setup, test rate, and pick up, are. On the NI. NI-DAQ™mxをダウンロードして、サポート情報をご確認ください。. According to the NI 9775 Datasheet it is also possible to use it with DAQmx, so you should be able to run it in a cDAQ-9178 chassis. 91 in. 5 mm pitch. It also controls the timing, synchronisation, and data transfer between C Series I/O modules and an external host. Many teams struggle to manage product quality within shorter and shorter time-to-market windows, but best-in-class test organizations are leading the way. This limits the system to two tasks with different oversample clock timebases. In this study, particular attention. 0 Readme. Call now for best pricing. 0 Chassis NI cDAQ-9171/9174/9178 User Manual July 2016 372838E-01 What I’m trying to do: I have a cDAQ-9178 chassis with 5 NI modules installed in the following slots: NI 9216 (using 8 channels: RTD sensors) NI 9237 (4 channels: strain gauge) NI 9421 (8 channels digital input: relay activation and process step reading) NI 9472 (4 channels digital output: relay group select) NI 9205 (Voltage input from. The Python module uses the. You can use this chassis with a combination of C Series I/O modules to create a mix of. 市場投入までの期間がますます短くなりつつある中、多くのチームは製品の品質を管理することに苦労していますが、クラス最高のテスト組織がその道を切り開いています。 8‑Slot, USB CompactDAQ Chassis. 05-28-2013 09:50 AM. It also controls the timing, synchronization, and data transfer between C Series I/O modules and an external host. 07-23-2018 12:13 PM. The cDAQ‑9178 is a CompactDAQ USB chassis designed for small, portable sensor measurement systems. Please note that while the 2D dimensional drawings are available for most parts numbers, the 3D models are not. The NI‑9213 is a high-density thermocouple input module that is designed for higher channel count systems. Launch Measurement & Automation Explorer. To perform simple input estimations, the user can simply insert a C Series module into any open slot on the cDAQ Chassis. A virtual channel is a collection of settings such as a name, a physical channel, input terminal connections, the type of measurement or generation, and can include scaling information. 2. CDAQ-9178, COMPACTDAQ CHASSIS (8. Make sure that the NI cDAQ-9178 power source is not connected. The chassis features the plug‑and‑play functionality of USB to connect sensor and electrical measurements. 50 1 $ 797. If the driver has been reinstalled, re-associate the driver to the device. Description. These specifications are typical at 25 °C unless otherwise noted. NI cDAQ-9178 Chassis and NI 9401 Digital I/O Module. NI cDAQ-9178 Dimensions 1 2 3 4 5 6 7 8 19. 49 in. Restart PC - Unplug the problematic device, reboot PC. You can use the digital module to access the counters on the cDAQ chassis, and generate a pulsetrain using those counters. cDAQ-9178 Product Certifications. I can't make it works and I've been wondering if the problem comes from me and how I create my program or if the problem is hardware. 16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module. Navigate to an example that matches one of the module's types from step 1 above, e. 3. これらは、ネットワーク全体で計測を同期できるデータ収集モジュールで構成されています。. 以下のビデオをご覧いただき、手順に従ってください。. More info, here. Install the module in slot 8 of the NI cDAQ-9178 chassis. LabVIEW was selected because it interfaces well with the NI modules. Refer to the Using Network Synchronization in Your Acquisition topic for more information. The cDAQ‑9178 is a CompactDAQ USB chassis designed for small, portable sensor measurement systems. Desktop Mounting - For any CompactDAQ chassis to facilitate the wiring and removal of I/O modules during development. By the way, I have two modules on the device, NI 9215 and NI 2963. Several Arduino modules described in section 4. . cDAQ-9178是专为小型便携式传感器测量系统而设计的总线供电CompactDAQ USB机箱。. cDAQ 9178 PFI Lines. CCA,CDAQ-9178,8 SLOT USB BACKPLANE (CDAQ-II) Symbol Description Certification; EU & UK Declarations of Conformity (DoC) PDF Demko, Product Safety: PDF KC, EMC: PDF UL, Product Safety:Open Device Manager by going to Start»Control Panel»System and Security»System and click Device Manager. The cDAQ‑9178 is a CompactDAQ USB chassis designed for small, portable sensor measurement systems. An NI cDAQ-9178 [9] crate houses these three NI modules and is connected to an SCMS PC via a USB cable. A programmable power source (Koard KA3005P) powers the heater. 53. The NI cDAQ-9178 (eight slots) and NI cDAQ-9174 (four slots) USB chassis are designed for use with C Series I/O modules. 1 Panel mounting is done without using a DIN-RAIL. Using the DAQmx driver, signals can be exported from a master task by using the NI-DAQmx Export Signal Property Node. (a) Aluminum tape coated sample at heating test. 3V, but rather the low state is at 1. 0 mm (0. This acquisition system is used in the sine sweep mode and an average over 300 cycles is used at each frequency step. It is worth noting that the temperature field of the T-OHP began oscillating at power inputs less than 60 W (as low as 40 W), but these thermal oscillations were not sufficiently steady until ∼60 W. 8 or later with the NI-9426 or the NI-9475 and are still seeing the. NI cDAQ-9178シャーシとNI9401デジタルI / Oモジュール. National Instruments 781156-01 CompactDAQ Chassis. Solution. 5” Spherically Mounted Retroreflector (SMR). 2. Select Change advanced power settings. Um in S-ESV die Versuche nach definierten Steifigkeitsreduktionen zu beenden, wurde ein DAQ-Modul (NI-9222) in Kombination mit einem cDAQ-Chassis (NI cDAQ-9178) der Fa. NI GPIBコントローラおよびGPIBポートを備えたNI組込コントローラをサポートします。. Title: NI cDAQ-9174/9178 USB Chassis Quick Start - National Instruments Author: Technical Communications Keywords: cDAQ-9178 USB chassis cDAQ9178 cDAQ 9178 9178 CompactDAQ-9178 CompactDAQ9178 CompactDAQ 9178 Compact DAQ-9178 Compact DAQ9178 Compact DAQ 9178 Compact-DAQ-9178 Compact-DAQ9178 Compact-DAQ 9178 9178 374849A-01 324849A-01 374849A 324849A 374849-01 324849-01 374849 324849 9178 cDAQ. 75 in. El chasis proporciona la simplicidad plug-and-play de USB a sensores y mediciones eléctricas. 8‑Slot, USB CompactDAQ Chassis. NI-DAQmx 19. Description Instead one of the 2 onboard PFI lines will be routed to the onboard counter. A valid service agreement may be required. External Trigger. Confirm that you have a physical DAQ device connected, the compatible N-DAQmx driver installed and you can see the device in NI MAX or have created simulated NI-DAQmx device available in MAX. 修理、RMA、キャリブレーション予定. Experimental condition. The device is in an NI cDAQ-9178 chassis in slot 3 with ID cDAQ1Mod3. 94 in. Power Supply Part Number: 190415B-01. CompactDAQシャーシから電源が接続解除されて. You can usually find 3D CAD models of NI hardware on the dimensional drawings page. I have been trying to use the NI 9411 device to measure frequency using the cDAQ counters. In its most basic form cDAQ is an IO extension for harsher environments than you would want a PC or PXI chassis. Connect the Hardware. National Instruments eingesetzt und ein LabView-Programm genutzt, das die Ausgabe von Kennwerten in Echtzeit ermöglicht. Capture a Unique Event in Incoming Data. This tutorial lists the C Series modules for the CompactDAQ product line and the CompactRIO product line. It also controls the timing, synchronisation, and data transfer between C Series I/O modules and an external host. Attach the other end of the wire to the system safety ground. The NI 9401 has a D-Sub connector that provides connections for the eight digital channels. ) 25. Provides support for NI data acquisition and signal. For ICPCs, a National Instruments (NI) cDAQ-9178 chassis with a NI9223 voltage digitaliser (Austin, TX, USA) was used in addition as seen similarly in a previous study. The chassis provides the plug‑and‑play simplicity of USB to sensor and electrical measurements. 2. In addition, the digital encoder waveforms from the servo motor were captured by a NI-9361 8 channel digital input module. cDAQ-9178. 88 in. NI-XNET is an NI instrument driver that features a common set of easy-to-use functions for reading and writing Automotive Ethernet, CAN, LIN, and FlexRay data on many different platforms including USB, PXI, PCI, NI CompactDAQ, and NI CompactRIO. The chassis provides the plug‑and‑play simplicity of USB to sensor and electrical measurements. Member. The chassis provides the plug‑and‑play simplicity of USB to sensor and electrical measurements. ステップ3. cdaq-9178 シャーシには 4 つのオンボードカウンタがあります。デジタルモジュール(例えばni 9401 または ni 9402)を接続せずにカウンタタスクを実行したいですが、物理チャンネルにリストされず、1つのオンボードカウンタにもアクセスできません。 4つのカウンタチャンネルにデジタル. Connect the power source to the NI cDAQ-9178 chassis. DAQmx is now updated to 9. It has high-channel density to reduce the number of modules needed, which leaves slots open for other measurement types or for reducing. Description. 最简单的解决方案是使用计数器的半周期测量. ハードウェアによってサポートされていないため、指定された経路を処理できません。. NI-DAQmx Release Notes: Known issues, bugs fixed since the last release, and other notes about this release. This CompactDAQ also controls the planning, synchronization, and. When I connect 4 of these sensors to my cDAQ 9178 with using 1 slot of NI 9219, then there is no problem for my VI. The cDAQ‑9178 is a CompactDAQ USB chassis designed for small, portable sensor measurement systems. FlexLogger does not currently support the built-in PFI lines on the cDAQ chassis, so you will have to use an input on one of your sensor modules as the trigger signal. (Color Online) Block diagram for the time/frequency impulse response. 修理、RMA、キャリブレーション予定. ) 23. It features USB or Ethernet bus connectivity and provides timing, synchronization, and triggering. Table 1. Als Nächstes geht es darum, wie die CompactDAQ-Hardware verbunden wird. To perform simple input estimations, the user can simply insert a C Series module into any open slot on the cDAQ Chassis. In MATLAB, the following. Combine the cDAQ-9178 with up to eight NI C Series I/O modules for a custom analog input, analog output, digital I/O, and counter/timer measurement system. g. The chassis provides the plug-and-play simplicity of USB to sensor and electrical measurements. 4 mm (1. A personal computer was employed for data storage and to control the experimental variables. Okay, thank you for the answers. The chassis provides the plug‑and‑play simplicity of USB to sensor and electrical measurements. When I look in the Windows Device Manager, the device has a yellow exclamation point and says USB Flash Firmware Loader. Timestamp based Start Trigger. The cDAQ‑9178 is a CompactDAQ USB chassis designed for small, portable sensor measurement systems. The chassis provides the plug‑and‑play simplicity of USB to sensor and electrical measurements. 그림에서 핀 0은 "아날로그 입력 0" 채널에 해당하고 핀 9는 공통 접지에 해당합니다. com I and Ins trumenta tion o r industry Resumen del producto. Options. NI PS-14 NI PS-15 NI PS-16 NI PS-17. Control a VFD via cDAQ 9178. The chassis provides the plug-and-play simplicity of USB to sensor and electrical measurements. lza_2331. Co. Sumantri Hatmoko, dkk. niでは、世界で最も困難な課題を解決する自動テストおよび計測システムを開発しています。お客様とともに、お客様の組織のこれからの100年に向けた創造的なソリューションのエンジニアリングを行います。Technical Sales #eská Republika 800 142 669 ni. 2 is the real photograph of the experimental setup. ; Click on Create Task. 88 in. It will also help if you see a red X next to where you had been able to see your cDAQ previously, or if you can't add your module to your network cDAQ chassis in NI MAX. , Winterthur, Switzerland), and were sampled at a rate of 1000 Hz with cDAQ-9178 (National Instruments Co. Para esta sección, considere un ejemplo usando el chasis NI cDAQ-9178 y el módulo de E / S digital NI 9401 Serie C. The cDAQ-9178 is a CompactDAQ USB chassis designed for small, portable sensor measurement systems. 0. 8‑Slot, Ethernet CompactDAQ Chassis —The cDAQ‑9188 is a CompactDAQ Ethernet chassis designed for small, distributed sensor measurement systems. Regards, Jens. Visit to learn more about the NI CompactDAQ USB Chassis. 図5は、ni cdaq-9178シャーシとni 9203を併用した基準化シングルエンド (rse) 電流測定の接続図とこのモジュールのピン配列を示しています。 図では、ピン0が「アナログ入力0」チャンネルに、ピン9がコモングランドに対応します。The AutoPGA program installed in PC1 communicates with the robot controller using 24 V digital output/input modules (NI 9477 and NI 9426) installed in NI cDAQ-9178. 35 in. 8 slots, USB 2. ) 23. Step 2: Connect the USB cord to number 1 above. NI Employee (retired) 12-19-2013 04:28 PM.